Make decisions faster and treat patients sooner with TRUFORMA®, the in-clinic biosensor testing platform.
TRUFORMA® is available as a complimentary device once you’ve completed the agreement form and returned it to leads@pioneervet.co.uk.
Take control over the testing process from start to finish.
- Gold standard results available at the point of care.
- TRUFORMA® assays adhere to the stringent testing standards found in reference lab settings levels, allowing you to diagnose challenging cases with confidence.
Equine ACTH – More Than Just eACTH:
When running Equine ACTH on TRUFORMA®, practices receive both:
- eACTH
- CLIP (Corticotropin-Like Intermediate Peptide)
CLIP provides additional diagnostic insight and is not routinely included in commercial laboratory eACTH testing.
By delivering both markers at the point of care, TRUFORMA® supports:
- More informed interpretation
- Enhanced assessment of PPID cases
- Immediate clinical decision-making
- Reduced need for repeat visits or delayed treatment adjustments
With results available in-clinic, practices can discuss findings with owners during the same appointment - improving workflow efficiency and case management.
Now, you can achieve reference lab performance levels - right in your clinic.
- Groundbreaking technology
- Put the same technology used in aerospace and telecommunications to work in your practice!
- Bulk Acoustic Wave (BAW) is an innovative, non-optical, fluorescence-free technology that delivers accurate, reliable results when assessing complex conditions.
TRUFORMA® requires minimal routine maintenance. As part of standard preventative maintenance, the air filter located on the rear of the instrument should be replaced monthly to ensure optimal performance.
To replace the air filter:
- Power off the instrument and unplug the power cable from the rear
- Use a flat-head screwdriver to remove the filter retainer (note the orientation - an arrow is moulded into the plastic)
- Remove and discard the used filter
- Insert a new filter (the filter is symmetrical and has no front or back)
- Refit the retainer, reconnect the power cable, and power the unit back on
Fan filters are available and are also included with new and replacement TRUFORMA® device shipments. Please click HERE to purchase our fan filters.
Guides & Tools
- Quick Start Guide - Get started using TRUFORMA
- Troubleshooting - Get help troubleshooting problems in TRUFORMA
- Instructions for Use - Instruction manual for TRUFORMA
- Routine Maintenance Log - Keep track of TRUFORMA maintenance tasks
Clinical Decision Support
- Adrenal Reference Ranges
- Equine Cortisol Reference Ranges and Interpretation Guide
- GI Reference Ranges
- Thyroid Reference Ranges
- Equine eACTH Reference Ranges
- Insulin Reference Ranges
- NT-proBNP Reference Ranges
- Canine Progesterone Reference Ranges
- Equine Progesterone Reference Ranges
Assay Instructions
Thyroid Assays:
- Total T4 (TT4) Test Instructions
- Free T4 (FT4) Test Instructions
- Thyroid Stimulating Hormone (TSH) Test Instructions
Adrenal Assays:
- Cortisol Test Instructions
- Equine Cortisol Test Instructions
- Canine Endogenous ACTH (eACTH) Test Instructions
- Equine Endogenous ACTH (eACTH) Test Instructions
GI Assays:
Insulin Assay:
Cardiac Assay:
Reproductive Assay:
White Papers
Thyroid Assays:
- Point-of-Care Canine and Feline Total Thyroxine (tT4) Assay
- Point-of-Care Canine Free Thyroxine (fT4) Assay
- Point-of-Care Canine and Feline Thyroid-Stimulating Hormone (TSH) Assay
Adrenal Assays:
- Point-of-Care Canine Cortisol Assay
- Point-of-Care Canine eACTH Assay
- Point-of-Care Equine eACTH Assay
- Point-of-Care Canine LDDST Grey Zone
GI Assays:
Insulin Assay:
Cardiac Assay:
Reproductive Assay:



